User Instructions for Hubi Premium Solar Power Station
Hubi Solar Power Station Premium FAQ
There is no power when the power station is switched on, what do I need to check?
Check the 30A system fuse and replace it as necessary. If the fuse is OK, double-check the battery using a multimeter and confirm it reads over 12V DC.
CAUTION: Unplug the solar panel and turn all the switches off before removing the cover and opening the power station.
There is no output from the DIN socket, USB ports or lighting sockets, what is wrong?
Check the 10A lighting fuse and replace it as necessary.
There is no mains output from the mains socket, how do I resolve this?
Check that both the system power switch and 220V switches are in the on positions. If they are, check the 30A system fuse and replace it as necessary. If the inverter is still off, check the 35A purple fuse built into the left side of the inverter and replace it as necessary.
CAUTION: Unplug the solar panel and turn all the switches off before removing the cover and opening the power station.
The battery doesn’t appear to be charging, what could be wrong?
Check the solar panel for contaminants, dirt etc. and if necessary, clean the solar panel with soapy water and a sponge as required.
It is always worth checking that the solar panel is not partially in shade, as this has a significant effect on the solar panel’s efficiency, so look for shadows from telegraph poles, trees etc and relocate the panel if shadows are cast upon the panel.
Check the solar panel connections are still firmly attached to the side of the power station.
Check the 16A in-line fuse holder between the charge controller and the battery and replace the fuse if necessary.
CAUTION: Unplug the solar panel and turn all the switches off before removing the cover and opening the power station.